The 6813B is ideal for applications such as power supply testing, UPS testing, avionics ATE, the testing of power factor corrected equipment and devices, and compliance testing to regulatory
standards.
6813B
Key Specifications
|
| Output ratings (maximum) |
Phases: 1
Power: 1750 VA
rms Voltage: 300 V
Frequency: dc; 45 to 1000 Hz
rms Current: 13 A
Peak Current: 80 A
Non-repetitve peak current: 80 A
dc Power: 1350 W
dc Voltage: +/- 425 V
dc Current: 10 A
Crest Factor: 6 |
| Constant Voltage Ripple
and noise (20 kHz to 10 MHz) |
-60 dB (relative to full
scale)
300 V rms |
| Maximum
Total Harmonic Distortion |
0.25% at
50/60 Hz
1% worst case (45 Hz to 1000 Hz) |
| Line regulation |
0.1% of full scale |
| Load regulation |
0.5% of full scale |
| Load
Power Factor Capability |
0-1 |
| Supplemental
Characteristics |
| Modes |
AC, DC,
and AC+ DC
Fixed, Pulse, Step, and List |
| Waveshape
(built-in) |
Sine,
Square, Clipped Sine, and user defineable |
| Arbitrary
Waveforms |
user
definable, save up to 12 in non-volatile memory |
Measurement
Capability
(16 bit resolution system) |
rms
Voltage, dc Voltage, ac + dc Voltage
rms Current, peak Current, Watts, VA, VAR
Frequency, THD, Power Factor, Crest Factor
Triggered acquisition of digitized voltage and current |
| Harmonic
Analysis of V and I |
Returns
amplitude, phase, and THD up to 50th harmonic |
| Instrument
States |
save up
to 16 states in non-volatile memory |
| Programmable
Output Impedance |
Resistance:
0 to 1 ohm
Inductance: 20 uH to 1 mH |
| Output
Relays |
Front
panel control, bus programmable |
| Average
Programming Resolution |
rms
Voltage: 125 mV
dc Voltage: 250 mV
rms Current Limit: 4 mA
Peak Current Limit 25A
Overvoltage: 2 V
Output Frequency: 10 uH |
Programmable
Slew Rates
(avg prog resolution) |
ac
Voltage Slew Rate (rms): 6 mV/s
dc Voltage Slew Rate: 20 mV/s
Frequency Slew Rate: 0.05 Hz/s |
| Output
Voltage Risetime |
50 Us
(10% to 90% or 90% to 10%, resistive load) |
| Average
Measurement Resolution |
rms
Voltage: 10 mV
rms Current: 2 mA |
| Isolation
to Ground |
300 Vrms
/ 425 Vdc |
| Remote
Sense |
up to 1
Vrms can be dropped on each load lead |
| Remote
Inhibit Response Time |
<15 ms |
| Regulatory
Compliance |
Listed
to: UL 3111-1
Certified to: CSA 22.2 No. 1010-1
Conforms to: IEC 1010 |
| RFI
Supression Complies with: |
CISPR-11,
Group 1, Class A |
| Input
Ratings |
| Voltage range (Vac) |
174 to 220 Vac (200/208 Vac nom.)
191 to 254 Vac (230
Vac nom.) - Factory default setting |
| Maximum input current
(rms) |
22 A (at 200/208 Vac)
20 A (at 230 Vac) |
| Input power (max) |
3800 VA / 2600 W |
| Input frequency |
47 to 63 Hz |
| Physical
Specifications |
| Net Weight |
32.7 kg (72 lb) |
| Shipping Weight |
36.4 kg (80 lb) |
| Dimensions |
425.5 mm W x 132.6 mm H x
574.7 D (16.75 in x 5.25 in x 22.6 in) |